Home-Spec Inspections LLC

                       ASHI Certified Home Inspectors

                             We inspect Colorado!   

 

                   Aurora Arvada Broomfield Boulder Denver Golden

                            Lakewood Littleton Parker Westminster

 

DCP_3453.jpg

 

                  Things that we inspect.

 

  Lot and vegetation

   Plant health, landscaping

   street noise and trash

 

   Roof  system

   Covering, flashing, gutters

   drainage and penetrations

 

   Exterior walls & Siding

   Siding, decks, patios, doors

   and storm drainage

 

   Electrical system

   Panels, wire, receptacles

   switches and infrared scans

 

   Heating and cooling Systems

   Expected life of furnace and AC,

   gas leaks, duct, registers

 

   

    Structure and foundation

Foundation walls, support

columns and concrete floors

 

    Interior walls and floors

Drywall, doors, cabinets,

stairs and handrails

 

    Insulation and ventilation

Insulation, vapor barriers,

attic and crawlspace vents

 

    Fireplaces and stoves

Clearances, fire brick

dampers and chimneys

 

    Radon and mold survey

We always look for conditions

favorable for mold growth or radon

and recommend tests if we think

either may be present

 

 

Our Inspections include checking hundreds of items

          Typical Checklist of items inspected

                          ROOF AND SKYLIGHTS

Inspection Method

Visual Walk-on

Roofing Material

Asphalt Shingle ~15 Years rated

Roof Coverage

OK

Roof Drainage

OK

Flashing

Galvanized Sheet Metal – some rust

Penetrations

Lead Flashing

Skylights

Snow Melting System Not Functional

Chimneys

OK – clean before first fire

Leakage

None Apparent

Gutters

Secure byut5 need to be cleaned

                                 Summary: Expect roof to last less than 10 years

 

                          STRUCTURAL SYSTEM

Inspection Method

Visual In Attic Space

Attic Structure

Manufactured Trusses – 24” centers

Ceiling Structure

Truss

Wall Structure

2x4 wood studs

Floor Structure

2x12 joist – 16” centers

Crawl Space Framing

2"x12" Joist on 10" Steel I-Beam

Basement Framing

Concrete wall – no insulation or furring

Foundation

8" Concrete

Columns

3” steel post – adjustable height

Concrete Floor

Concrete – few cracks, no vertical movement

                                  Summary: Attic structure appears to be sound. No dry rot or water damage

                                      was seen. One roof truss appeared to be missing. Strongly recommend

                                      that a structural engineer be consulted.

 

 

                                EXTERIOR WALLS AND SIDING

Paint/Stain

Repainting Recommended in 2-3 Years

Siding

Masonite 8" Lapp Siding With Rock; Damaged

Doors

Solid wood – Minor cracks – re-paint

Decks/Porches

OK – replace hand railing on east side

Soffits/Eaves/Facias

Some dry rot – repair and repaint

Trim

Will need paint soon

Caulking

No caulking observed around most windows

Walkways

Concrete

Patios

None

Driveway

Concrete, Some Cracking, No Indication of Recent vertical movement

Vegetation

Lawn and Trees Generally Healthy

Grading

Gentle Slope

Surface Drainage

Generally Away From House

Retaining Walls

None

Garage Door Em Switch

Functional

Lighting

Typical

                               Summary: Recommended caulk around windows in rear of house. Broken

                                rock on front. Small cracks in driveway. Cracks do not appear to be continuing.

 

                          INTERIOR WALLS, FLOORS & STAIRS

Ceiling

Slight Crack Between Sheetrock & Glu-Lam Beam

Walls

Spackle Textured - Average Condition

Floors

Appear Level - Some Creaking in Living Room

Doors

OK

Windows

Double pane with aluminum frame

Stairs

OK

Railing

Need to provide additional support near top

Cabinets

Secure and Level

Counters

Counter Near Refrigerator Needs Re-caulking

Fire Walls & Doors

Fire Door Between Kitchen and Garage Needs Adjusting

Closet Space

Typical

                                Summary: Some small cracking in sheetrock near Glu-Lam beam and in

                                 kitchen counter.

 

                           ELECTRICAL SYSTEM

Main Panel Make

GE

Service Amps/Volts

125 Amps, 120/240 Volts

Overhead/Underground

Underground

Main Switch Location

East Side

Circuit Breakers

4 Spares

Circuit Labels

Very Brief. Current Owner Should Label Breakers

Service Wire

Aluminum - Typical

Branch Wire

Copper

Panel Infrared Scan

OK - Max Temperature: 61F

Service Grounding

OK

Ground Fault System

3 Receptacles Tested - Functioned Normally

Receptacle Polarity

10 tested -OK

Receptacle Grounding

10 Receptacles Tested - Grounding OK

Light Fixtures

Typical

Light Switches

5 Switches Functioned Normally

Smoke Detectors

One Located Above Stairs

Telephone Service

Cable TV Service

                                Summary: Recommend adding more smoke detectors to all bedrooms.

                                   Panel size is slightly small for this house...

 

                         PLUMBING SYSTEM

Interior Water Piping

1/4" & 3/4" Copper

Main Water Valve

Located on the right side of the water heater near the ceiling.

Fixtures & Faucets

Checked 4 - Functioned Normally

Tub/Shower

Some water damage at base of tub

Toilets

Fill Valve in Master Toilet Needs Replacing

Water Pressure

OK - Greater than 30 PSI

Sewer Piping

ABS

Sewer Venting

ABS

Water Heater

State, 40 GAL

Energy Source

Gas

Water Heater Venting

OK

Fuel Storage/Piping

Black Pipe - Standard

Main Fuel Valve

Outside Near Electrical meter

Drainage Sumps

None

Sump Pumps

None

Noise

Average

Leaks

None observed

Piping Insulation

Hose Bibs

Freeze proof

Laundry Hook-ups

Electric For Dryer

                              Summary: No evidence of water damage in the shower/bathtub areas.

                               However, most enclosures leak after several years. Water heater appears

                                in good condition.

 

                        HEATING SYSTEM

Type

Carrier- Forced Air

Energy Source

Gas

Combustible Gas Test

Less Than 5 PPM

Carbon Monoxide Test

Less Than 5 PPM - Normal

Heat Distribution

Uniform Duct

Size

Adequate For House Size

Noise

Average

Humidifier

OK – set below 30% to prevent mold growth

Filter

Needs Cleaning